| Availability: | |
|---|---|
| Quantity: | |
TLX
purestar
Produced from selected high-quality bituminous coal through fine grinding, extrusion molding, carbonization and controlled activation, TLX features a hierarchically developed pore structure and high mechanical integrity. Its porous surface provides physical adsorption capacity for SO₂, NOₓ and particulate matter, while inherent surface catalytic sites promote oxidation of sulfur dioxide into sulfuric acid in the presence of oxygen and water vapor, achieving efficient dry desulfurization without chemical additives.
Available in standard 5mm and 9mm cylindrical specifications, TLX maintains ≥97% abrasion resistance and high compressive strength, resisting particle breakage under long-term airflow scouring and frequent thermal regeneration cycles. Its stable performance under typical industrial flue gas temperatures makes it suitable for large-scale continuous-operation flue gas purification systems.
Parameter | TLX | Unit |
|---|---|---|
Iodine adsorption value | ≥ 350 | mg/g |
Moisture content | ≤ 3.0 | % |
Ash content | < 20 | % |
Bulk density | 550 ~ 650 | kg/m³ |
pH | 9.5 ~ 11.5 | - |
Abrasion resistance | ≥ 97 | % |
Compressive strength | ≥ 40 | daN |
Fire point | ≥ 440 | ℃ |
Desulfurization value | ≥ 20 | mg/g |
Denitration rate | ≥ 40 | % |
Specific surface area | 310 ~ 400 | m²/g |
Volatile matter | ≤ 3 | % |
5mm
7mm
9mm
1000 kg/bag
Integrated desulfurization & denitrification performance
Combined physical adsorption and surface catalytic action achieves efficient removal of SO₂ and NOₓ in a single dry treatment process, avoiding wastewater generation.
≥97% ultra-high mechanical strength
Excellent compressive and abrasion resistance minimizes particle attrition and dust generation during long-term operation and repeated regeneration cycles.
High-temperature flue gas adaptability
Stable performance under typical industrial flue gas temperature ranges, suitable for dry treatment without additional gas cooling equipment.
Thermally regenerable for long service life
Supports multiple thermal regeneration cycles to restore adsorption capacity, significantly reducing long-term operating cost for large flue gas systems.
Power Plant Flue Gas Ultra-Low Emission Compliance: Coal-fired boilers must meet stringent SO₂ and NOₓ standards. TLX's dry desulfurization and denitrification process achieves >90% SO₂ removal without generating wastewater, avoiding the secondary pollution and high operating costs of wet scrubbing systems.
Steel Sintering Flue Gas Treatment: Sintering operations produce high-temperature, high-dust flue gas that destroys conventional activated carbon. TLX's activated coke structure maintains integrity to 200°C while providing integrated pollutant control in a single dry bed.
Industrial Boiler & Kiln Emission Control: Chemical, metallurgical and building materials industries need flue gas purification without cooling gas streams. TLX's high-temperature stability supports direct dry treatment, eliminating energy-intensive gas cooling equipment.
Coking Plant Waste Gas Treatment: Coking operations release sulfide, dust and organic pollutants. TLX's combined adsorption and catalytic action handles these complex streams in integrated systems.
Dry treatment process generates no wastewater, eliminating secondary pollution and reducing overall system cost compared to wet desulfurization.
High mechanical strength and wear resistance support long-term operation in moving bed systems with 3–5 times longer service life than ordinary granular carbon.
Uniform pore structure and stable surface activity ensure consistent desulfurization efficiency across long operating cycles.
Available in custom impregnated grades for enhanced denitrification or heavy metal removal, adaptable to complex flue gas compositions.
PURESTAR adheres to strict quality control and international certification standards. Our authentic certifications include:
ISO 9001: Quality Management System
ISO 14001: Environmental Management System
ISO 45001: Occupational Health & Safety Management System
NSF: Certified for drinking water safety & sanitation
HALAL: Certified for food-contact applications
MSDS (Material Safety Data Sheet) available upon request
COA (Certificate of Analysis) provided with every shipment
All products undergo strict quality inspection to deliver stable, reliable performance for global customers.
10+ years of experience in activated carbon manufacturing and export
Stable production capacity ensuring reliable supply for bulk orders
Strict quality control system from raw material to final product
Customized solutions based on different industrial applications
Fast response within 12–24 hours for all inquiries
Professional technical support for product selection and application guidance
Q: What is the difference between TLX and SRC series?
A: SRC series is designed for low-temperature ambient air odor and H₂S removal. TLX is engineered for high-temperature industrial flue gas desulfurization and denitrification with higher mechanical strength and thermal stability. For flue gas mercury control, DIOSORB-S is recommended.
Q: Can TLX be thermally regenerated?
A: Yes. TLX supports multiple thermal regeneration cycles. Under proper conditions, it retains over 80% of original performance after repeated regeneration, greatly reducing long-term media cost.
Q: What particle sizes are available?
A: Standard specifications are 5mm and 9mm diameter columnar particles matching most fixed bed and moving bed systems. For lower-temperature odor control, SRC-A or SRC-BL 4mm carbon is recommended.